Scope
This part of IEC 62595 specifies the standard measurement conditions and measuring methods for determining the electrical and optical parameters of LED backlight units for liquid crystal displays.
Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 61747-30-1, Liquid crystal display devices – Part 30-1: Measuring methods for liquid crystal display modules – Transmissive type
IEC 62595-1-2, Display lighting unit – Part 1-2: Terminology and letter symbols 1
Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 62595-1-2 apply.
Abbreviations
BLU backlight unit
FOV field of view
LMD light measuring device
LSF light spread function
Luminance
The measurements should be carried out in the dark room under the standard measuring conditions and for the design viewing directions, as follows:
a)Position the BLU.
b) Adjust the LMD to the specified viewing direction, according to angles 0 and .
c) Supply the value of the input signals to the BLU. Then measure the BLU at position p, to obtain the luminance L (0,φ). (In case of i=0, the position implies the centre of the active area of the BLU.)
The LMD should be carefully checked before measurements, considering the following
elements:
sensitivity of the measured quantity to the measuring light;
errors caused by veiling glare and lens flare (i.e., stray light in an optical system);
timing of data-acquisition, low-pass filtering and aliasing-effects;
linearity of detection and data-conversion;
measurement size and field of view (FOV).
To ensure luminance accuracy for the intended LED sources, a broad bandwidth LMD should be calibrated using a spectrometer with a bandwidth 5 nm or less.
The luminance of BLU should be measured by synchronizing the LMD with the BLU refresh rate, or integrating the measured luminance over a number of frames.
Chromaticity
CIE 1931 chromaticity coordinates (IEC 60050-845:1987, 845-03-28 [3] and ISO 11664-1 [4]), x, y, z on the BLU surface of the active area are obtained using the tristimulus values, X, Y, Z calculated from measured spectral power distribution S(2) given in 5.2.4 (see IEC 62595-1-2). The correlated colour temperature (CCT) can also be used.
NOTE Correlated colour temperature (CCT) is defined in IEC 60050-845:1987, 845-03-50. The calculation method from the measured chromaticity data is specified in CIE publication 15:2004 [5]. Robertson’s [6] procedure is available for an actual computing program.
This measurement is carried out usually on on the axis normal to the surface of the BLU, however, other angles can also be considered for certain purposes.
LISUN following instruments fully meet IEC 62595-2-1 Display lighting unit -Part 2-1: Electro-optical measuring methods of LED backlight unit:
Your email address will not be published. Required fields are marked *
© Copyright 2003 | Blog | Privacy
surge generator | emc test system | emi receiver | electrical safety tester | temperature chamber | salt spray test | environmental chamber | Sitemap

To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.

中文简体