LSG-1900B goniophotometer is near field type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is used for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.


Near Field Goniophotometer Measurement:
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Lsocandela Diagrams, Efficient Luminescence Angle, etc.
Specification:
• It meets the requirements of CIE, IEC, IES LM-79 & GB standards
• It can do C-γ and B-β measurement
• The luminaires under test will keep the burning point from moving
• The luminaries under test rotates around an angle of (γ) ±180° (or 0-360°) and the luminaries rotates around itself with an angle of (C) ±180° (or 0-360°)
• Maximum size of luminaires under test: Φ300mm (diameter)×550mm (height); Weight: 20kg; Current: 10A
• Distance from lamp to detector: 1250mm
• Luminosity Testing Range: Light Intensity 0.015cd~10^7cd (detector)
• The accuracy of angle: 0.2°; The resolution of angle: 0.01°
• Accuracy of photometry: Class A
• English version software can run in Win7, Win8, Win10, Win11
• LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be transferred by other illumination and luminaire design software such as DiaLux
Tags:LSG-1900B , Near Field Moving Detector Goniophotometer Brochure
ANSI/IES LM-31-20 Photometric Testing for Roadway and Area Lighting Luminaires Using Incandescent or High Intensity Discharge Lamps need to use LISUN goniophotometer, integrating sphere and...
ANSI/IES LM-75-19 Approved method: guide to goniometer measurements and types, and photometric coordinate systems need to use LISUN goniophotometer, integrating sphere and spectroradiometer system to...
ANSI/IES LM-72-20 Directional Positioning of Photometric Data need to use LISUN goniophotometer, integrating sphere and spectroradiometer system to test
ANSI/IES LM-73-18 Photometric Testing of Entertainment Lighting Luminaires Using Incandescent Filament Lamps or High Intensity Discharge Lamps need to use LISUN goniophotometer, integrating sphere...
ANSI/IES LM-10-20 Photometric Testing of Roadway and Area Lighting Fluorescent Luminaires need to use LISUN goniophotometer, integrating sphere and spectroradiometer system to test
ANSI/IES LM-66-20 Electrical and Photometric Measurements of Single-Based Fluorescent Lamp need to use LISUN goniophotometer, integrating sphere and spectroradiometer system to test
ANSI/IES LM-35-20 Photometric Testing of Floodlights Using High Intensity Discharge or Incandescent Lamps need to use LISUN goniophotometer, integrating sphere and spectroradiometer system to test
ANSI/IES LM-20-20 Photometry of Reflector Type Lamps need to use LISUN goniophotometer, integrating sphere and spectroradiometer system to test
ANSI/IES LM-37-20 Guide for Determination of Average Luminance (Calculated) for Indoor Luminaires need to use LISUN goniophotometer, integrating sphere and spectroradiometer system to test
ANSI/IES LM-45-20 Electrical and Photometric Measurements of General Service Incandescent Filament Lamps need to use LISUN goniophotometer, integrating sphere and spectroradiometer system to test