
LM-79 Moving Detector Goniophotometer (Mirror Type C)
LSG-6000

High Precision Rotation Luminaire Goniophotometer
LSG-1890B

High Precision Rotation Luminaire Goniospectroradiometer
LSG-1890BCCD

Goniophotometer for Automotive and Signal Lamps
LSG-1950

Goniophotometer for Traffic Signal Lamps
LSG-1950S

Compact Goniophotometer
LSG-1200A

Near Field Moving Detector Goniophotometer
LSG-1900B





















Select an organization
to browse standards
IEC 62041:2010 sets forth the electromagnetic compatibility (EMC) requirements for transformers, power supplies, reactors, and similar products. This standard covers a wide range of equipment, including power transformers, auto – transformers, and power supplies, and applies to products with rated input voltages not exceeding 1000 V AC or 1500 V DC. It defines both emission and immunity requirements, aiming to ensure that these products do not cause electromagnetic interference to other equipment and can maintain normal operation in an electromagnetic environment. The standard also classifies the operating environments into different categories, each with specific EMC limits and test methods.
The emission requirements in IEC 62041:2010 focus on limiting the electromagnetic disturbances generated by the products, such as conducted and radiated emissions. Meanwhile, the immunity requirements specify the ability of these products to withstand electromagnetic disturbances from external sources. By establishing these EMC requirements, the standard helps to ensure the compatibility and reliable operation of transformers, power supplies, reactors, and similar products in various electrical and electronic systems, promoting the overall electromagnetic environment stability.

Transformer Test Solution
LISUN supplies the fully test solutions for the following IEC 62041:2010, please see the below excel table:
| IEC 62041:2010 Clause and Subject | LISUN MODEL |
| 5.1.2.2 Electrostatic discharges | ESD61000-2 |
| 5.1.2.3 Radiated, radio frequency electromagnetic field | GTEM-2 |
| 5.1.2.4 Electrical fast transient/burst | EFT61000-4 |
| 5.1.2.5 Conducted disturbances, inducted by radio-frequency fields | RFCI61000-6 |
| 5.1.2.6 Surge | SG61000-5 |
| 5.1.2.7 Voltage dips and short interruptions | CSS61000-11 |
| 5.2 Emission | EMI-9KB |
Your email address will not be published. Required fields are marked *
© Copyright 2003 | Blog | Privacy
surge generator | emc test system | emi receiver | electrical safety tester | temperature chamber | salt spray test | environmental chamber | Sitemap

To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.

中文简体