This standard IEC 60598-2-10:2003 applies to portable luminaires designed for children’s use, such as bedside lamps and toy lamps. It requires that the luminaire structure avoids sharp edges, risks of pinching, and the possibility of small parts being swallowed. Surface temperature limits are also set to prevent burns. In terms of electrical safety, the luminaires must have adequate insulation protection, operate at a safe voltage to prevent electric shock risks, and feature power cords with sufficient mechanical strength to resist pulling or damage.
The standard IEC 60598-2-10:2003 specifies testing methods to verify the safety of luminaires, including stability tests, electric shock protection tests, heat resistance tests, and mechanical strength tests. The materials used in the luminaires must meet flame resistance requirements and pass drop, pressure, and twisting tests to ensure safety under normal use and potential misuse by children. Additionally, the light sources must comply with relevant safety standards to avoid harming children’s eyesight. Product labeling and instructions should clearly indicate the applicable age range and usage precautions.
IEC 60598-2-10: 2003 Luminaires – Part 2-10: Particular requirements – Portable luminaires for children
LISUN supplies the fully test solutions for the following IEC 60598-2-10:2003, please see the below excel table:
| IEC 60598-2-10: 2003 Luminaires – Part 2-10:Particular requirements – Portable luminaires for children | LISUN MODEL |
| Clause 10.6.7 Figure 13 of IEC 61032 | SMT-1819 |
| Clause 10.7 Creepage distances and clearances | CK-1 |
| Clause 10.12 Endurance tests and thermal tests | GDJS-015B |
| Clause 10.13 Resistance to dust, solid objects and moisture | SC-015 |
| JL-X | |
| Clause 10.14 Insulation resistance and electric strength | WB2681A |
| Clause 10.15 Resistance to heat, fire and tracking | ZRS-3H |
| ZY-3 | |
| TTC-1 |
Your email address will not be published. Required fields are marked *
© Copyright 2003 | Blog | Privacy
surge generator | emc test system | emi receiver | electrical safety tester | temperature chamber | salt spray test | environmental chamber | Sitemap

To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.

中文简体