This report CIE 121:1996 covers general requirements for the photometry of luminaires which are considered to be applicable to most types of luminaire.
The report CIE 121:1996 sets out to provide specifications for the standard conditions under which photometric tests should be carried out and to recommend testing procedures which will give sufficiently accurate and reproducible resuits when determining and reporting the photometric characteristics of luminaires. These specifications are intended to provide a basis for uniform national standards and to give guidance to photometric laboratories in the conduct of tests and in the presentation of luminaire performance data. The report also gives specifications for the measurement of correction factors applicable to luminaires operated under practical test conditions different from the standard test conditions.
LISUN supplies the fully test solutions for the following CIE 121:1996, please see the below excel table:
| CIE 121:1996 The Photometry And Goniophotometry Of Luminaires | LISUN MODEL |
| Clause 2.2.1 Luminaire data per 1 000 lm (of lamp flux) | LPCE-2(LMS-9000) |
| Clause 2.2.4-2.2.7 Light output ratio (of a luminaire) | |
| Clause 6.3 Luminous flux measurements on luminaires | |
| Clause 2.2.2 Luminous intensity distribution (of a luminaire) | LSG-6000 |
| Clause 2.4.1-2.4.3 Photometer | |
| Clause 3 CO-ORDINATE SYSTEMS FOR THE PHOTOMETRY OF LUMINAIRES | |
| Clause 6.1.3 Photometric measurements on luminaires | |
| Clause 6.2 Luminous intensity distribution measurements | |
| Clause 2.2.3 Ballast lumen factor | HCS-109A |
| Clause 2.3.6 Reference ballast | |
| Clasue 7.4 Ballast lumen factor | |
| Clause 2.4.4 Illuminance meter | LMS-6000&PHOTO-200 |
| Clause 6.6 Illuminance measurements | |
| Clause 6.3 Luminous flux measurements on luminaires | LMS-6000L&PHOTO-200L |
Your email address will not be published. Required fields are marked *
© Copyright 2003 | Blog | Privacy
surge generator | emc test system | emi receiver | electrical safety tester | temperature chamber | salt spray test | environmental chamber | Sitemap

To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.

中文简体