+8618117273997weixin
EnglishEnglish
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語

GET A QUOTE

=

UL 507 UL Probe for Film-coated Wire

Product No: SMT-PA135A

  • Specifications
  • Standards
  • Applications
  • The UL 507 PA135A Probe is a specialized safety tool designed to test the insulation integrity of film-coated wires. The probes referenced in Table 9.1 and illustrated in Figures 9.1 and 9.2 shall be used as measuring instruments to judge the accessibility to uninsulated live parts and film-coated wire provided by openings and not as instruments to judge the strength of a material. Force is not to be applied to the probe when judging accessibility.

    Specifications:
    Probe Type: UL 507 PA135A Probe (for film-coated wire insulation integrity testing in fans/blowers)
    Handle Material: Nylon (fully insulating, heat-resistant up to 100°C; non-slip grip for precise pressure control)
    Key Dimensions:
    – Head Length: 12.7mm(1/2 inch)
    – Total Length: 101.6mm(4 inch)
    – The Head Radius: 14.3mm(9/16 inch)
    – Former Head Diameter: R4.8mm(3/16inch)
    – The Tail Diameter: 19.1mm(3/4 inch)

    Test Procedures:
    1. Inspect the probe (no bent tip, cracked handle, or poor conductivity) and connect it to a leakage detection instrument.
    2. Prepare the film-coated wire (from fan/blower) – clean, dry, and secure on a non-conductive surface.
    3. Hold the insulating handle and align the brass tip with the wire’s film coating.
    4. Glide the probe lightly along the wire’s entire length, maintaining consistent contact.
    5. Monitor the detection instrument for signals (indicating coating defects and electric leakage).
    6. Record defective sections and confirm if the wire meets safety requirements (pass/fail).

    Applications:
    1. Safety testing of film-coated wires in household pedestal fans and table fans (per UL 507:2023 Figure 8.6).
    2. Verification of film-insulated wires in ceiling fans and exhaust fans (kitchen/bathroom) for U.S. markets.
    3. Post-production audits of commercial air circulator wires to ensure insulation integrity per UL 507 standards.

    UL 507 UL Probe for Film-coated Wire

    UL 507 UL Probe for Film-coated Wire

     

    Tags: , , ,
  • ASKAREL - A genenic tem for a group of nonfammable synthetic chlornated hydrocarbons useds eleotrical insulaing meda. Askarels of various compoilional types 8re u8ed. Under arcing condions the...
    These requirements cover movable and wall- or ceiling-hung electric room-heating equipment rated 600 volts or less to be employed in ordinary locations In accordance with the National Electrical...
  • Cable and Wire Test Solutions

    LISUN's cable and wire test solutions are essential for verifying compliance with international...

    Household Applicances Test Solutions

    LISUN's household appliance testing solutions are fully compliant with IEC 60335, the fundamental...

    Plugs and Sockets Test Solutions

    LISUN's plugs and sockets test solutions are designed to ensure compliance with key international...

    LEDs and Luminaire Test Solutions

    LISUN's indoor and outdoor LED luminaires and LED fixtures test solutions fully cover key...