Articulated Test Probe of UL 1993 Figure 9.3

Product No: SMT-PA100A

  • Specifications
  • Download
  • Standards
  • Applications
  • Technology
  • The Articulated Test Probe of UL 1993 Figure 9.3 is a critical safety tool tailored for medical electrical equipment—like infusion pumps, patient monitors, and ultrasound machines. It mimics human finger movement via a flexible articulated design, using a 25.4mm stainless steel test finger to navigate tight gaps (e.g., device chassis seams or control panel slots) and detect accessible hazardous live parts or hot components. The probe features a 12.7mm rounded head (to avoid damaging delicate medical gear) and an insulated nylon handle for operator safety, with a 31.75mm tail diameter that prevents over-insertion. Applying a gentle 10N thrust to simulate accidental contact, it strictly complies with global medical safety standards, making it essential for validating device safety.

    Specifications:
    Tool Type: Articulate Test Probe (UL 1993 Figure 9.3; for hazardous part accessibility testing in medical electrical equipment)
    Material: stainless steel and nylon
    Key Dimensions:
    – Test finger diameter: 25.4 mm (1 inch)
    – Test finger length: 101.6 mm (4 inch)
    – Head radius: R12.7 mm (1/42 inch)
    – Tail diameter: 31.75 mm (1-1/4 inch)
    Joint Characteristics: Articulated design; max bending angle: 90° ± 10° (single plane/direction); maintains flexibility under 10N thrust
    Applied Thrust: 10N ± 0.5N (simulates gentle accidental contact; aligns with medical device safety requirements)
    Core Function: Detects accessible hazardous live/hot parts in medical equipment; mimics human finger movement; ensures compliance with global medical safety standards

    Test Procedures:
    1. Inspect the probe for loose joints, bent fingers, cracked insulation, or surface scratches; confirm conductivity with a test tool.
    2. Power on the medical device under test (EUT, e.g., a patient monitor) and set it to normal operating mode.
    3. Hold the nylon handle, use the articulated joint to guide the 25.4mm finger into EUT gaps (chassis seams, control slots).
    4. Apply steady 10N thrust—stop if resistance blocks insertion or the probe’s tail touches the EUT.
    5. Check the connected live-part detector for signals (indicating contact with hazardous parts).
    6. Record results: Pass if no contact; Fail if the probe reaches dangerous components.

    Applications:
    1. Testing access to live circuits in infusion pump casings (per UL 1993:2023 Figure 9.3) to prevent electric shock to patients or staff.
    2. Verifying control panel gaps in patient monitors (compliant with CSA C22.2 No. 1993:2023) to block contact with internal wiring.
    3. Safety checks for ultrasound machine transducer ports (per IEC 61032:2017 Figure 2) to avoid exposure to hot components.
    4. Quality control for blood glucose meter casings during manufacturing, ensuring UL 1993 compliance.
    5. Post-production testing of medical centrifuges to meet global medical electrical equipment safety rules.

    Articulated Test Probe of UL 1993 Figure 9.3

    Tags: ,
  • SMT-9A100A Calibrate Certificate
  • UL 2075:2021 is a key safety standard by Underwriters Laboratories for gas and vapor detectors and sensors intended for ordinary environments, covering both portable and stationary models. It...
    UL 2034:2024 is the latest US safety standard for single and multiple station interconnected carbon monoxide (CO) alarms. It sets mandatory electrical safety requirements for CO alarms, including a...
    UL 496:2013 is a safety standard governing lampholders for incandescent, fluorescent, and other discharge lamps, along with related parts like lamp shade holders and GU24/GU24-1 bases for LED...
    UL Standard for Safety for Light Emitting Diode(LED)Equipment for Use in Lighting Products,UL8750 Second Edition,Dated December 7, 2022
    This Standard UL 1598: 2012 is issued jointly by the Association of Standardization and Certification (ANCE), the Canadian Standards Association (CSA),and Underwriters Laboratories Inc. (UL).
    These requlrements are Intended to cover both sel-ballasled lamps and slballasted lamp adapters rated 120 to 347 V AC nominal for connection to screw-base, pin-base, or recessed single contacl (RSC...
  • Lamp Holder Test Solutions

    There are some standards focus on specifying technical requirements and test methods for different...