Equipment introduction:
Automatic Electrical Safety System can test for Withstand Voltage (AC/DC), Insulation Resistance (IR), Leakage Current (LLC), Ground Resistance (GR) and Power.

Application:
It is used for luminaries, home application and motor tools safety test in production line or R&D Lab.
Standard:
The LS9955/LS9956 Automatic Electrical Safety Tester is according to GB4706.1, IEC/EN60335-1, UL60335, GB7000, IEC60598, GB4943, IEC60950 and GB9706.1.
Based on years of experience in the production of LED test equipment, LISUN has developed a fully automatic safety tester. And has been exported to many countries around the world. The specific parameters are as follows:
|
Withstand Voltage Test (AC/DC) |
Insulation Resistance Test (IR) |
||||
|
Voltage Range |
Accuracy |
Current Range |
IR Range |
Accuracy |
Voltage Range |
|
100~4000V |
± (5%+3V) |
AC: 0.10~20.00mA |
1.00~2000MΩ |
5% + 0.5MΩ |
DC100~1000V |
|
Leakage Current Test (LLC) |
Grounding Resistance Test (GR) |
||||
|
LLC Range |
Accuracy |
Voltage Range |
GR Range |
Accuracy |
Output Current |
|
0.10~20mA |
± (0.3%+5uA) |
AC10.0~300.0V |
0~600mΩ |
± (5%+2mΩ) |
AC1.00~30.00A |
|
Power Test |
|||||
|
Voltage |
Current |
Power |
PF |
Accuracy |
Test Time |
|
10~300V |
0.010~20.00A |
1.0~6000.0W |
0.2~1.0 |
Class 0.5 |
0~999.9s |
Notes:
Pls. note that the DC high voltage output is a negative voltage, and the ground is a positive. When testing capacitance, there is a charging process when voltage is applied to both ends of the capacitor. At this time, there is a charging current in the test circuit. When the current is greater than the set leakage current value, the withstand voltage tester will alarm to interrupt the test , it cannot be proceed. Therefore, when the safety tester is testing, the voltage should be increased slowly, and the charging current should be less than the set leakage current value until the test voltage is specified, and the test should be performed. It is not possible to use a fixed voltage, reset-start method for testing. In the AC circuit, it is equivalent to the resistance in the DC circuit. Therefore, the safety tester generates a current in the AC circuit when the current is greater than the set leakage current When the value is set, the withstand voltage tester will alarm, making the test interrupted and unable to proceed. Therefore, before the test, you should first calculate the capacitive reactance (Xc) of the capacitor, and then calculate the loop current value under the test voltage, and then adjust the leakage current preset value of the withstand voltage tester to make it slightly larger than the loop current value. And then carry out testing. Test cables and other components (equipment) with large distributed capacitance should be equivalent to capacitor test.
Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.
Our main products are Goniophotometer, Surge Generator, EMC Test Systems, ESD Simulator, EMI Test Receiver, Electrical Safety Tester, Integrating Sphere, Temperature Chamber, Salt Spray Test, Environmental Test Chamber, LED Test Instruments, CFL Test Instruments, Spectroradiometer, Waterproof Test Equipment, Plug and Switch Testing, AC and DC Power Supply.
Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp: +8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp: +8618917996096
Your email address will not be published. Required fields are marked *
© Copyright 2003 | Blog | Privacy
surge generator | emc test system | emi receiver | electrical safety tester | temperature chamber | salt spray test | environmental chamber | Sitemap

To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.

中文简体